CONFIDENTIAL_EO-49_-_Pump_Overhaul_EUL_PA_Response_1_CPUC_Response_3_Redacted.pdf
|
2026 May 18
|
Complete |
Closed |
2026 Sep 3
|
The EO seeks approval of an updated non-DEER EUL for pump overhauls based on analysis of historical pump performance data. |
Based on the updated analysis and available data, the estimated pump-specific EUL values range from approximately 5.7 to 11.3 years. The available evidence supports the conclusion that the efficiency benefits associated with pump overhauls persist for at least 5 years. However, CPUC staff note that the degradation dataset remains limited. CPUC staff may reassess the EUL with an updated degradation analysis after at least six months of additional data collection. A larger dataset with longer post-overhaul degradation histories will support a more robust estimate of measure EUL in the future. |
2026 Nov 16
|