Early Opinions History

Title: Updated Non-DEER EUL for Pump Overhaul

File EO Submission Date EO Status Court CPUC Final Decision Date EO Issue(s) / Question(s) Brief Overview of CPUC Conclusion Date Posted
CONFIDENTIAL_EO-49_-_Pump_Overhaul_EUL_PA_Response_1_CPUC_Response_3_Redacted.pdf 2026 May 18 Complete Closed 2026 Sep 3 The EO seeks approval of an updated non-DEER EUL for pump overhauls based on analysis of historical pump performance data. Based on the updated analysis and available data, the estimated pump-specific EUL values range from approximately 5.7 to 11.3 years. The available evidence supports the conclusion that the efficiency benefits associated with pump overhauls persist for at least 5 years. However, CPUC staff note that the degradation dataset remains limited. CPUC staff may reassess the EUL with an updated degradation analysis after at least six months of additional data collection. A larger dataset with longer post-overhaul degradation histories will support a more robust estimate of measure EUL in the future. 2026 Nov 16